<LOGO>
FM Transmitter Measurement Report
Created: 2024-08-09 06-40-23
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 56 dBuV SANDELS
Pilot RDS Phase Difference
6.7 kHz 5.8 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
16 kHz 50 kHz 3592 0,1670
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,4 dBr 2,69 dBr 3,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 9 --:--
RT
-
AF EON
92.0, 94.7, 98.5, 106.3, 107.5 MHz -
FM Scope Max at: 50 kHz MIN: 16 kHz % above 76 kHz: 0,1670 Acquired: 2024/08/09 6.39.19 Total samples: 3592 Equivalent time: 0:02:59 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100
FM Scope MAX: 3,6 dBr MIN: 0,4 dBr AVE: 2,69 dBr % above 12,2 dBr: 0,0 Last value: 3,1 dBr (2024/08/09 6.39.18) 06.26 06.28 06.30 06.32 06.34 06.36 06.38 -1 0 1 2 3 4 Pm [dBr]